Schoonover, Inc.

Home Page

Products   Represented  Companies Contact Us

Apex Vacuum Battery Powered Portable Mass Flow Meter



Portable Mass Flow Meter Battery Powered

Field engineers now have an easy way to measure and verify flow of installed instruments.


Companies spend time and money to verify that installed equipment in the field is working properly. In most cases, the equipment has to be removed from service and sent to a metrology lab or an in house testing center for verification. Removal of installed equipment takes time and in some cases requires that the process be shut down for removal and in some cases stay down until the device under test is returned from testing.
 

The Apex Battery Powered Mass Flow Meter can be powered off standard 9V DC batteries. Battery life is approximately 6-8 hours

One Instrument…Accurate..Repeatable for 30 On-Board Gases

Text Box: 30 factory installed, user selectable, gas calibrations:
                            Air
                            Argon
                            Methane
                            Carbon Monoxide
                            Carbon Dioxide
                            Ethane
                            Hydrogen
                            Helium
                            Nitrogen
                            Nitrous Oxide
                            Neon
                            Oxygen
                            Propane
                            Butane
                            Acetylene
                            Ethylene
                            Iso-Butane
                            Krypton
                            Xenon
                            Sulfur Hexaflouride
                            75% Argon + 25% C02
                            90% Argon + 10% C02
                            92% Argon + 8% C02
                            98% Argon + 2% C02
                            75% Argon + 25% Helium
                            75% Helium + 25% Argon
                            75% CO2 + 25% Argon
                            Helistar® A1025
                            Stargon® CS

 

 

 

 

 

 

 

 

 

Text Box: What makes us different?
30 User Selectable Gases- More flexibility for the customer 
Fast Response- 10 millisecond   response,  100 milliseconds to control 
Addressable RS-232 Interface- Control 26    units with one RS-232 port 
 FlowVision Windows Software- Control any MFC/MFM through a computer and graph flow
 Pinpoint Accuracy- 0.2% Full Scale plus 0.8% Reading, provides excellent accuracy 
100-1 Turndown Ratio- Combined with the pinpoint accuracy allows for lower flow readings 
Flows as low as 0.5 sccm Full Scale 
 Lower Cost - More features but not more costly

 

 

 

Text Box: What makes us different?
30 User Selectable Gases- More flexibility for the customer 
Fast Response- 10 millisecond   response
Addressable RS-232 Interface- Control 26    units with one RS-232 port 
 FlowVision Windows Software- Control any MFC/MFM through a computer and graph flow
 Pinpoint Accuracy- 0.2% Full Scale plus 0.8% Reading, provides excellent accuracy 
100-1 Turndown Ratio- Combined with the pinpoint accuracy allows for lower flow readings 
Flows as low as 0.5 sccm Full Scale 
 Lower Cost - More features but not more costly

For models and online pricing:

Apex Potable Battery Powered Mass Flow Meter: 0.5sccm    1 sccm   2 sccm   5 sccm   10 sccm 

                                                                  20 sccm   50 sccm   100 sccm  200 sccm   500 sccm

                                                                  1 slpm   2 slpm   5 slpm   10 slpm   20 slpm

                                                                  50 slpm   100 slpm             

Other Information:

 

Options for Mass Flow Meters

Power Cables- Communication Cables

Control Software- LabView Drivers

 

Apex Mass Flow Meters- Product Literature

 

Apex Mass Flow Meter Basic Specifications

Apex Mass Flow Meter Manual

Frequently Asked Questions

 

 

The Apex Mass Flow Controllers and Apex Mass Flow Meters are designed to be used in vacuum systems where precise gas flow is required. Applications include, vacuum coating, CVD Processes, PVD Processes, e-beam thin film deposition, sputtering, vacuum sputtering, thin film sputtering, thermal evaporation. Also thin film, optical coating, cathodic arc sputtering and magnetron sputtering.

Apex Vacuum Mass Flow Controllers and Mass Flow Meters are also used in pressure control and vacuum pressure control processes. The Apex Mass Flow Controller outputs and inputs allow the user to replace other mass flow controllers and mass flow meters such as MKS, Brooks, Celerity, Unit, Sierra and Hastings

 

Also can be used in leak detection systems for mass flow leak detection systems and with a pressure controller Pressure Decay Leak Detection Systems.

 

Try Apex Vacuum today in vacuum coating applications.

Apex Mass Flow Controllers


 Copyright 2000-2008 Schoonover, Inc. of Atlanta Georgia serving the Southeast since 1963.

Phone us at 770-479-7138
E-mail:  info@schoonoverinc.com

 

AddFreeStats.com Free Web Stats in real-time !