The ChargeIT determines that the product
being leak tested does not have a gross leak by
1) Performing a pressure decay and
vacuum decay leak test. The helium charging system then
2) Pulls a vacuum on the system before
back-filling with helium gas (or mixture helium-nitrogen). The ChargeIT
actually allows the user to
3) Choose the mixture of helium to
nitrogen ratio. Once complete with the helium leak test, the ChargeIT
allows the
4) Venting of the test unit to a
recovery system. The area can then be
5) Cleaned by air or nitrogen.
The ChargeIT can be used in either
vacuum leak testing or sniffing leak detection
|